Install fit
Phase support Single-phase two-wire (1P2W) and three-phase four-wire (3P4W); 100-277 V L-N or 100-480 V L-L, 50/60 Hz. Single-phase 1-phase 2-wire / 230 V L-N system for the selected MID variant.
Installation Indoor 72 mm / four-module DIN-rail direct connection; default top-in/bottom-out wiring. Indoor 2-DIN DIN-rail mounted direct-connected single-phase energy analyzer.
Measurement True-RMS 1P2W/3P4W voltage, current, power and bidirectional import/export energy measurement. Direct-connected single-phase active/reactive energy analyzer with imported/exported energy measurement and RS485 Modbus RTU.
Max current 100 A 100 A
Meter fit
Accuracy class Active energy Class 1.0 / Class B; reactive energy Class 2; MID certified. Active energy Class 1 / Class B; reactive energy Class 2.
Current sensing Direct-connected whole-current meter; no external CTs required. Direct connection 5(100) A; no external CTs for EM112DINAV01XS1PFB.
Monitoring
Protocol RS485 Modbus RTU / pulse output RS485 Modbus RTU / pulse output
Local API Yes Yes
Cloud dependency No vendor cloud required; local readings are available through RS485 Modbus RTU and pulse outputs. No vendor cloud required for core metering; readings are available locally through RS485 Modbus RTU and pulse output hardware paths.
Home Assistant Yes Yes
Solar fit
Solar import/export Yes Yes
Buying context
Availability Global Eastron product range; certification, stock, and suffix availability vary by market. Carlo Gavazzi global product channels; country pages, MID/UKCA availability, stock, and distributor routes vary by region.
Source check
Last verified Aug 26, 2026 Jul 16, 2026
Product page Official page Official page